C-63
Byte
k
1
:
bit 8: = 0 fixed
bit 7: = 1 fixed
bit 6: = 0 values of k1 k2
1 default values
bit 5: = 0 one retry
1 three retries
bit 4: = 0 End of Sentinel = 0F
1 End of Sentinel = 0C
bit 3: = 0 fixed
bit 2-1: = 00: IBM 3604
01: DIN/ISO
10: ANSI
11: Reserved
Byte
k
2
:
bit 8: = 0 fixed
bit 7: = 1 fixed
bit 6: = 0 duplication OFF
1 duplication ON
bit 5: = 0 fixed
bit 4: = 0 fixed
bit 3: = 0 fixed
bit 2-1: = 00: standard position
01: position + 10 mm
10: position + 20 mm
11: Reserved
The command is not accepted (command specification error) if:
It is sent inside a printing field.
The device is not present.
A device other than the front paper stand is selected.
Seitenansicht 204