Commands
77
ESC @
Initializes the printer. (EPSON)
ASCII Code ESC @
Hexadecimal Value 1B 40
Decimal Value 27 64
This sequence causes the printer:
• to go back to the current printer setup settings
• to cancel any selected print attributes
• to reset the column counter
• to set the horizontal tabulations every 8 columns
• to clear all vertical tabulations
Only the selection of Draft/Quality printing, DLL and the selected character generator are
maintained.
ESC [ K
Sets initial conditions. (IBM 2391 + only)
ASCII Code ESC [ K
n
1
n
2
init id
Hexadecimal Value 1B 5B 4B
n
1
n
2
init id
Decimal Value 27 91 75
n
1
n
2
init id
This command causes the printer to reset to its initial status:
n
1
,n
2
The n
1
and n
2
parameters specify the number of bytes in the escape sequence normally,
n
1
= 2 and n
2
= always 0.
init
The init parameter specifies to which condition the printer should initialize, normally
init = 0,1,4,5,254,255.